Key Clinical Summary

  • Aortic coarctation with multiple aneurysms can prevent crossing from either direction using a single approach.
  • When antegrade and retrograde attempts fail, complementary partial crossings may reach a common intervening aneurysm, where snare capture can establish an arterio-arterial rail for wire exchange and stent delivery.
  • Successful crossing does not resolve stent landing-zone challenges; proximal-edge narrowing and endoleak may require reintervention despite symptomatic improvement.

Abstract

Aortic coarctation with multiple post-stenotic aneurysms can pose substantial challenges to guidewire crossing. The authors describe a 30-year-old man with hypertension, exertional dyspnea, and claudication in whom computed tomography demonstrated a stenotic coarctation segment followed by 5 aneurysms. Attempts to traverse the entire diseased segment from radial and femoral approaches were unsuccessful because the hydrophilic guidewire repeatedly coiled within the aneurysmal sacs. Both approaches could nevertheless access a common aneurysm, where a femorally introduced snare captured the radially advanced guidewire. Externalization connected the partial crossings into an arterio-arterial rail, enabling wire exchange and covered-stent delivery. At 3 months, proximal-edge narrowing with minimal endoleak required a second covered stent. At 1 year after reintervention, the patient remained asymptomatic, with a peak Doppler gradient of approximately 36 mm Hg. Unlike snaring after successful complete antegrade traversal, intraneurysmal capture established continuity between 2 incomplete crossings. This case illustrates a technical adaptation for complex aneurysmal coarctation while highlighting the separate challenges of proximal lesion coverage and follow-up surveillance.


 

Introduction

Multiple aneurysms distal to an aortic coarctation can complicate guidewire advancement and prevent complete traversal of the diseased segment. Previous reports describe successful antegrade traversal followed by snare-assisted establishment of an arterio-arterial rail.1,2 We describe an intraneurysmal rendezvous in which capture within a common aneurysm connected complementary partial crossings when neither approach independently traversed the entire diseased segment.

Technical Report

Patient presentation and imaging

A 30-year-old man with a 10-year history of hypertension presented with 4 months of exertional dyspnea and bilateral lower-limb claudication after walking approximately 500 meters. Upper- and lower-limb blood pressures were 170/100 and 104/76 mm Hg, respectively, with radiofemoral delay and diminished femoral pulses. Transthoracic echocardiography demonstrated concentric left ventricular hypertrophy, preserved systolic function, and a peak descending aortic Doppler gradient of 80 mm Hg.

Computed tomography (CT) aortography demonstrated a stenotic coarctation segment immediately distal to the left subclavian artery, followed by 5 aneurysms (Figure 1). Vessel dimensions and potential proximal and distal landing zones were assessed. Following heart team discussion, endovascular repair was planned with surgical backup.

 

Figure 1. Preprocedural computed tomography (CT) assessment of coarctation with post-stenotic aneurysms.
Figure 1. Preprocedural computed tomography (CT) assessment of coarctation with post-stenotic aneurysms. (A) Three-dimensional CT aortogram demonstrated the coarctation and associated aneurysmal segment. (B) Two-dimensional CT image showed 5 post-stenotic aneurysms (numbered boxes); the 2 small adjacent aneurysms are jointly labeled “4,5.” Measurement boxes on the right display proximal and distal aortic diameters used for landing-zone assessment and covered-stent sizing.

 

Intraneurysmal rendezvous and covered-stent implantation

The procedure was performed under local anesthesia using right radial and right femoral arterial access. Initial angiography demonstrated the coarctation and associated post-stenotic aneurysms (Video 1, Figure 2A). Attempts to traverse the entire diseased segment from either direction with a 0.035-inch hydrophilic guidewire (Terumo) were unsuccessful because the wire repeatedly entered and coiled within the aneurysmal sacs. Both approaches could nevertheless access a common aneurysm.

A 15-mm gooseneck snare (Medtronic) was advanced through a 6F Judkins Right catheter (Cordis) from the femoral access into this aneurysm. From the radial access, a hydrophilic guidewire was directed through a 6F multipurpose catheter (Cordis) into the same aneurysm (Video 2). The wire was captured and externalized through the femoral sheath, connecting the partial crossings into a continuous arterio-arterial rail across the diseased segment (Figure 2B, Video 3).

A 6F pigtail catheter (Cordis) was advanced over the rail across the lesion, permitting angiographic delineation and exchange for 260-cm Amplatz Super Stiff guidewire (Boston Scientific) positioned in the ascending aorta. A 14F delivery system (Cook Medical) was introduced (Video 4). Predilation was performed with a 10 × 60-mm MAXI LD balloon (Cordis) (Video 5). Angiography was performed to assess covered-stent positioning before deployment (Video 6). A 57-mm covered stent mounted on a 14 × 60-mm balloon (NuMED) was then deployed across the diseased segment (Figure 2C, Video 7).

Completion angiography demonstrated exclusion of the aneurysms and preserved left subclavian flow (Figure 2D, Video 8). The residual invasive gradient was 18 mm Hg. The patient was discharged the following day on aspirin 75 mg daily and antihypertensive therapy.

 

Figure 2. Index endovascular repair
Figure 2. Index endovascular repair using intraneurysmal rendezvous and covered-stent implantation. (A) Angiogram showing coarctation (yellow arrow) and post-stenotic aneurysms (green arrows). (B) Snare capture of the radially advanced guidewire within the third aneurysm. (C) Covered-stent deployment. (D) Completion angiogram showing aneurysm exclusion and preserved left subclavian artery flow (yellow arrow).

 

Follow-up and reintervention

The patient remained asymptomatic at 3 months, but echocardiography demonstrated proximal stent narrowing with a peak Doppler gradient of 65 mm Hg (Figure 3A). CT and angiography confirmed proximal-edge narrowing with minimal endoleak into the proximal aneurysm (Figure 3B).

A second covered stent mounted on a 16 × 45-mm balloon (NuMED) was implanted, overlapping the initial stent proximally and partially covering the left subclavian origin while preserving flow (Figure 3C and 3D). The residual invasive gradient after reintervention was 24 mm Hg. Clopidogrel 75 mg daily was added to aspirin for 12 months after reintervention.

 

Figure 3. Proximal-edge narrowing
Figure 3. Proximal-edge narrowing at 3 months and covered-stent reintervention. (A) Continuous-wave Doppler recording demonstrated a peak gradient of 65 mm Hg across the stented segment. (B) Angiogram showed proximal-edge narrowing of the initial covered stent (arrow). (C) Positioning of a second covered stent overlapping the proximal end of the initial stent. (D) Completion angiogram showed partial coverage of the left subclavian artery origin with preserved flow.

 

At 1 year after reintervention, the patient remained asymptomatic with stable blood pressure. Echocardiography demonstrated a peak Doppler gradient of approximately 36 mm Hg across the stented segment. Aspirin monotherapy was continued after completion of the planned course of dual antiplatelet therapy.

 

Discussion

The principal technical challenge was complete traversal of the coarctation and associated aneurysmal segment. Neither antegrade nor retrograde passage independently traversed the entire diseased segment, but both approaches reached a common aneurysm where snare capture connected the partial crossings.

In previously published reports, antegrade traversal preceded snare-assisted establishment of an arterio-arterial rail.1,2 In the present case, capture did not simply retrieve a wire after complete traversal; it established continuity between 2 incomplete crossings. The aneurysm therefore acted both as an obstacle to guidewire advancement and as a shared capture site. Externalization subsequently permitted catheter passage and exchange for a supportive wire. The technical contribution is the adaptation of established snaring techniques to complete crossing through an intermediate rendezvous site.

Although covered balloon-expandable stents achieve high procedural success and improve hemodynamic outcomes, recoarctation and other complications remain possible.3 Endovascular treatment can relieve coarctation and exclude associated aneurysms, although proximal landing-zone limitations may complicate preservation of the left subclavian artery.4 In the present case, the initial covered stent excluded the aneurysms while preserving left subclavian flow, but proximal-edge narrowing and minimal endoleak required reintervention.

Proximal extension with a second covered stent preserved left subclavian flow, but a residual invasive gradient of 24 mm Hg remained. At 1 year after reintervention, the patient was asymptomatic, with a peak Doppler gradient of approximately 36 mm Hg. These measurements were obtained using different modalities and should not be interpreted as directly equivalent, nor should symptomatic improvement be equated with complete hemodynamic normalization.

This single case cannot establish the comparative safety or reproducibility of intraneurysmal rendezvous. Its applicability depends on a common capture site accessible from both directions and the feasibility of subsequent catheter passage, wire exchange, and definitive treatment. Nevertheless, it illustrates how intraneurysmal capture can establish continuity when neither approach independently traverses the entire diseased segment. The subsequent course also underscores the importance of proximal lesion coverage and continued aortic imaging surveillance after intervention, including in patients without recurrent symptoms.5

 

Affiliations and Disclosures

Pranav Tirumalai N C, MD, DM; Arkit Deep Singh, MD; Parag Wamanrao Barwad, MD, DM; Sanjeev H. Naganur, MD, DM; Bhupendra K. Sihag, MD, DM

From the Department of Cardiology, Advanced Cardiac Centre, Postgraduate Institute of Medical Education and Research, Chandigarh, India.

Acknowledgments: The authors used Perplexity AI to assist with restructuring and editing the abstract, clinical summary, procedural narrative, and discussion. The authors reviewed and edited the resulting content and take full responsibility for the final manuscript.

Disclosures: The authors report no financial relationships or conflicts of interest regarding the content herein.

Consent statement: The authors confirm that written informed consent was obtained from the patient for the interventions described in the manuscript and for publication of the patient’s data, including all accompanying images and videos.

Address for correspondence: Parag Wamanrao Barwad, MD, DM, Department of Cardiology, Level 3, Advanced Cardiac Centre, Postgraduate Institute of Medical Education and Research, Chandigarh 160012, India. Email: paragaims@gmail.com


 

References

  1. Jata B, Jahollari A, Kojqiqi A, Huti G. Coarctation of aorta and post-stenotic dissecting aortic aneurysm successfully treated with endovascular stent. Int Med Case Rep J. 2020;13:367-370. doi:10.2147/IMCRJ.S267692
  2. Stecko W, Wańczura P, Nowak A, Sabiniewicz R. Beyond the guidelines. Advanced endovascular therapies in a most challenging aortic coarctation case. Cardiol J. 2026;33:e00226006. doi:10.5603/cj.102385
  3. He F, Cao Z, Wang C, et al. Endovascular treatment of aortic coarctation using covered balloon-expandable stents-a systematic review and meta-analysis. Front Cardiovasc Med. 2024;11:1439458. doi:10.3389/fcvm.2024.1439458
  4. Pan J, Liu Y, He Y, et al. Endovascular treatments for coarctation of the aorta with concurrent poststenotic aneurysms in adults. Ann Vasc Surg. 2022;87:446-460. doi:10.1016/j.avsg.2022.05.023
  5. Isselbacher EM, Preventza O, Hamilton Black J III, et al. 2022 ACC/AHA guideline for the diagnosis and management of aortic disease: a report of the American Heart Association/American College of Cardiology Joint Committee on Clinical Practice Guidelines. J Thorac Cardiovasc Surg. 2023;166(5):e182-e331. doi:10.1016/j.jtcvs.2023.04.023